Composite Cables 
LSZH Sheathed Composite Cable Data Pairs SWB LSZH Sheathed Composite Cable DVI Digital Dual Link Cable DVI Rolling Stock Cable

 Composite Cables

 

RG59 Coaxial Cable + 2C0.75 NYM Cable + 1P18AWG Instrumentation Cable + 1C18AWG Grounding Cable

+ Messenger Wire Unarmored PVC Elastomer Sheathed Elevator Composite Cable

 

Application:

CCTV composite cable armoured CCTV composite cable is mainly used in the CCTV application connection. It can

be used to connect the CCTV control system to the CCTV cameras. The steel armour braiding provides added

protection to the cable while the LSZH outer jacket provides flame-retardant capability in the event of a fire

breakout.

Construction:

RG59 Coaxial Cable + 2C0.75 NYM Cable + 1P18AWG Instrumentation Cable + 1C18AWG Grounding Cable + Messenger Wire Unarmored PVC Elastomer Sheathed Elevator Composite Cable

75Ohm RG59 Coaxial Cable

Conductor:Copper Clad Steel Conductor

Insulation:Polyethylene

Shield:Braid of bare copper wire, coverage ≥ 85%

Sheath:PVC elastomer

Sheath Color:Black

 

2C0.75MMSQ NYM 500V

Conductor:Flexible stranded copper

Insulation:PVC. Thickness 0.6mm

Insulation Color:Blue and Brown

Sheath:PVC elastomer. Thickness 0.6mm. Gray color

 

1P18AWG Instrumentation Cable 300V

Conductor:Flexible stranded copper

Insulation:XLPE. Thickness 0.6mm

Insulation Color:Blue and White

Shield:Braid of bare copper wire, coverage ≥ 85%

Sheath:PVC elastomer. Thickness 0.6mm

Sheath Color:Black

 

1C18AWG Grounding Cable 300V

Conductor:Flexible stranded copper conductor

Insulation:PVC. Thickness 0.6mm

Insultion Color:Green/Yellow

 

Messenger Wire

Conductor:Stranded steel wire

Insulation:PVC. Thickness 0.6mm

Insultion Color:Black

 

Element Assembly

Outer Sheath:Extruded PVC elastomer. Thickness 2.5mm.

Overall Diameter:Nominal outer diameter 21.0±2.0mm

Sheath Color:Black. Other color available as per request

 

Electrical and Physical Properties @20°C:

RG59 Coaxial Cable

Impedance: 75±3Ohm (@1MHz)

Max. Attenuation: 7.5dB/100m @50MHz

2C0.75MMSQ NYM Cable

Working Voltage: 500V

Test Voltage: 2000V

Insulation Resistance: >20 MOhmxkm

1P18AWG Instrumentation Cable

Working Voltage: 300V

Test Voltage: 1500V

Insulation Resistance: ≥1000 MOhmxkm

Note: Other configurations, sizes, colors and length not specified herein are available upon request.